Our 105th Year! |
1-800-328-5689 |
Apr 2020 • Issue #663 |
![]() Dry Cleaning |
![]() On-Premise |
![]() Coin-Op |
![]() MCC News |
April 2020 Bulletin
COVID-19: THE MINNESOTA CHEMICAL CO is open for supply, washer/dryer parts and washer/dryer service Monday through Friday. We are here to help keep your laundry running in these difficult times.
Shipping and receiving WILL NOW BE OPEN Fridays (starting the week of April 27th!).
We are proud to send out our April 2020 Monthly Bulletin—we hope you enjoy it. This bulletin includes information on:
|
|
Service Tips from Ed JensenPower Supply Boards on Milnor Washers |
|
I get a lot of calls on Milnor washers where customers say when they start a formula the washer goes into a countdown. They can’t start a formula. Or they say they don’t have a display. These are common problems that relate to power supply boards or display.
When a machine goes into a countdown this could mean one of two things: First power supply board may be out of adjustment or the power supply is bad. The power supply board should be adjusted at 5.07 to 5.10 DC. If you don’t have a display that could mean your control fuse is bad or the power supply is bad or display board is bad. First check out your fuses. If fuses are good then the power supply or the display board is bad. That means it’s time to call for service! |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|